General
DDS226D-4P M type single phase din-rail multi-features energy meter is designed for adapting our state power network, especially for energy separate metering and energy efficiency management. This meter can accurately and directly measure active total energy power, real-time current, voltage, active power, power factor and frequency. Four type rates and 14 day times can be set, and adjust it according to the relevant rates, and reserve 12 months data. It is very suitable for measuring the power consumption of school dormitory and shopping mall store.

Chint electric energy meter)

Function and features
1.Measure single-phase active total power, four rates active total power, 12 months data reserve, read by RS485 communication software.
2.Measure the real-time current, voltage, power, active power, power factor, frequency.
3.Four times rate and 14 day times setting.
4.LCD 8 digits display: 999999.99kWh.RS485 communication interface (DL/T645-2007 communication protocol, Modbusprotocol is selectable)
5.Far-infrared communication interface, read the meter data by hand console.
6.Passive impulse output
7.35mm standard DIN rail mount.



DIN rail mount


Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse with...

AC load-break switch / outdoor 40.5 kV | FZ77-40.5D/T1250-20 / FZR77-40.5D/T63-31.5

AC load-break switch / outdoor 40.5 kV | NFZ77-40.5D/T1250-20 / NFZR77-40.5D/T63-31.5 Skype : mark2002719   email : mark2002719@gmail.com FZ77-40.5D/T1250-20 / FZR77-40.5D/T63-31.5 Outdoor AC Vacuum Load Break Switch  Application: for making and breaking rated current and overload current, protecting the equipments from phase-loss fault in 35kV AC50Hz power system. Standards: IEC 60265-1, IEC 62271-105. Parameters:  Rated voltage: 40.5kV  Rated current: 1250A  Fuse current: 63A Features:   Compact design and light in weight.   High breaking capacity.   Maintenance-free.   Safety and reliable operation.   Long mechanical life.

DC to AC Solar Power Inverter

              DC to AC Solar Power Inverter Products Features 1. Input & output fully insolated 2. High Surge: High surge current capability starts difficult loads such as TVs, camps, motors and other inductive loads 3. Soft start: Smooth start-up of the appliances. 4. Pure sine wave output waveform: Clean power for sensitive loads. 5. AC output identical to, and in some cases better than the power supplied by your utility 6. Cooling fan in the inverter is thermally activated and comes on when the inverters becomes warm, and turns off automatically after the inverter has cooled. 7. Low total harmonic distortion: Below 3% 8. Two LED indicators on the front panel shows the working and failure state.