Skip to main content

DDS226D-4P M Single-phase Din-rail Multi-function Energy Meter

DDS226D-4P M Single-phase Din-rail Multi-function Energy Meter(Chint electric energy meter)


General
DDS226D-4P M type single phase din-rail multi-features energy meter is designed for adapting our state power network, especially for energy separate metering and energy efficiency management. This meter can accurately and directly measure active total energy power, real-time current, voltage, active power, power factor and frequency. Four type rates and 14 day times can be set, and adjust it according to the relevant rates, and reserve 12 months data. It is very suitable for measuring the power consumption of school dormitory and shopping mall store.

Chint electric energy meter)

Function and features
1.Measure single-phase active total power, four rates active total power, 12 months data reserve, read by RS485 communication software.
2.Measure the real-time current, voltage, power, active power, power factor, frequency.
3.Four times rate and 14 day times setting.
4.LCD 8 digits display: 999999.99kWh.RS485 communication interface (DL/T645-2007 communication protocol, Modbusprotocol is selectable)
5.Far-infrared communication interface, read the meter data by hand console.
6.Passive impulse output
7.35mm standard DIN rail mount.



DIN rail mount


Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse withstand vol

Load-break switch 12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5

Load-break switch   12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5     Skype : mark2002719   emal : mark2002719@gmail.com FLN36-12D/630-20 SF6 Switch / FLRN36-12D/T125-31.5 SF6 Switch-fuse Combination Application: in the system of 50Hz, 12kV for making and breaking of load current, over-load current and short-circuit current to control and protect the circuit and transformer, etc. Standards: IEC 60265, IEC 60420 Features:  Indication of the active contact to show the operation status of the switch.   High insulation level.   Fully sealed and reliable operation. Technical Data:  Rated voltage(kV): 12  Rated current(A): FLN36-12D: 630; FLRN36-12D: 125  Rated frequency(Hz): 50  Rated short-time withstands current of switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/3  Rated short-time withstands current of earthing switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/2   Rated peak withstand current and rated short-circuit making

earth fault breaker/ID RCCB

ID-I earth fault breaker/ID RCCB 1,Provides protection against earth fault/leakage current and function of isolation High breaking current withstand capacity. 2,Applicable to terminal and pin/fork type busbar connection. 3,Equipped with finger protected connection terminals. 4,Fire resistant plastic parts endures abnormal heating and strong impact. 5,Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity Independent of power supply and line voltage, and free from external interference, voltage fluctuation. Technical Data   Mode Electro-magnetic type, electronic type Residual current characteristics A, AC Pole No. 2, 4 Rated making and breaking capacity 630A Rated current(A) 16 25 40 63 80 100A Rated voltage 240/415V AC Rated frequency 50/60Hz Rated residual operating current IΔn(mA) 10, 30, 100, 300, 500 Rated residual non operating current IΔno 0.5IΔn Rated conditional breaking current Inc 6000A Ra