Skip to main content

earth fault breaker/ID RCCB

ID-I earth fault breaker/ID RCCB
1,Provides protection against earth fault/leakage current and function of isolation High breaking current withstand capacity.
2,Applicable to terminal and pin/fork type busbar connection.
3,Equipped with finger protected connection terminals.
4,Fire resistant plastic parts endures abnormal heating and strong impact.
5,Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Technical Data
 
ModeElectro-magnetic type, electronic type
Residual current characteristicsA, AC
Pole No.2, 4
Rated making and breaking capacity630A
Rated current(A)16 25 40 63 80 100A
Rated voltage240/415V AC
Rated frequency50/60Hz
Rated residual operating current IΔn(mA)10, 30, 100, 300, 500
Rated residual non operating current IΔno0.5IΔn
Rated conditional breaking current Inc6000A
Rated conditional residual breaking current IΔc6000A
Tripping durationInstantaneous tripping≤0.1s
Residual tripping current range0.5IΔn~IΔn
Electro-mechanical endurance4000 cycles
Connection capacityRigid conductor up to 25mm2
Connection terminalScrew terminal
Pillar terminal with clamp
Fastening torque2.0 Nm
InstallationOn symmetrical DIN rail 35mm
Panel mounting

ID RCCB

Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse withstand vol

Load-break switch 12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5

Load-break switch   12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5     Skype : mark2002719   emal : mark2002719@gmail.com FLN36-12D/630-20 SF6 Switch / FLRN36-12D/T125-31.5 SF6 Switch-fuse Combination Application: in the system of 50Hz, 12kV for making and breaking of load current, over-load current and short-circuit current to control and protect the circuit and transformer, etc. Standards: IEC 60265, IEC 60420 Features:  Indication of the active contact to show the operation status of the switch.   High insulation level.   Fully sealed and reliable operation. Technical Data:  Rated voltage(kV): 12  Rated current(A): FLN36-12D: 630; FLRN36-12D: 125  Rated frequency(Hz): 50  Rated short-time withstands current of switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/3  Rated short-time withstands current of earthing switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/2   Rated peak withstand current and rated short-circuit making