Skip to main content

earth fault breaker/ID RCCB

ID-I earth fault breaker/ID RCCB
1,Provides protection against earth fault/leakage current and function of isolation High breaking current withstand capacity.
2,Applicable to terminal and pin/fork type busbar connection.
3,Equipped with finger protected connection terminals.
4,Fire resistant plastic parts endures abnormal heating and strong impact.
5,Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Technical Data
 
ModeElectro-magnetic type, electronic type
Residual current characteristicsA, AC
Pole No.2, 4
Rated making and breaking capacity630A
Rated current(A)16 25 40 63 80 100A
Rated voltage240/415V AC
Rated frequency50/60Hz
Rated residual operating current IΔn(mA)10, 30, 100, 300, 500
Rated residual non operating current IΔno0.5IΔn
Rated conditional breaking current Inc6000A
Rated conditional residual breaking current IΔc6000A
Tripping durationInstantaneous tripping≤0.1s
Residual tripping current range0.5IΔn~IΔn
Electro-mechanical endurance4000 cycles
Connection capacityRigid conductor up to 25mm2
Connection terminalScrew terminal
Pillar terminal with clamp
Fastening torque2.0 Nm
InstallationOn symmetrical DIN rail 35mm
Panel mounting

ID RCCB

Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse with...

DDS226D-4P Single-phase Din-rail Energy Meter

DDS226D-4P Single-phase Din-rail Energy Meter (same quality as Chint energy meter) DDS226D-4P Single-phase Din-rail Energy Meter (same quality as Chint energy meter) General DDS226D-4P type single-phase din-rail energy meter can accurately and directly measure 50Hz/60Hz active energy consumption from single phase AC electricity net with functions of good reliability, small volume, light weight, specious appearance,convenient installation, etc. All of the performances accord with the National Standard GB/T17215.321-2008 and International Standard IEC62053-21. Function and features  1.Measuring single phase total active energy power. 2.May select step motor type impulse register display 5+1 digits (99999.9KWh) or LCD 5+2 digits display, LCD 5+2(99999.99KWh), 5+1 digits(99999.9KWh) and 6+1 (999999.9KWh); 3.Passive impulse output, comply to DIN43864 Standard; 4.Two LED indicate power condition and energy impulse signal; 5.35mm standard DIN rail i...

CM1 MCCB Circuit breaker(moulded case circuit breaker)

CM1 MCCB Circuit breaker(moulded  case circuit breaker) (Same quality as Chint electric circuit breaker/mccb) General  of 2 poles mccb       MCCB: Moulded Case Circuit Breaker , These are using at High rating currents from 63A to 1600A ,with short circuit and earth leakage protection (Same quality as Chint electric circuit breaker/mccb)     1.1 Electric ratings: AC 690V, 50/60Hz, 10~800A;     1.2 Mounting mode: vertical and horizontal;     1.3 Standard: IEC/EN 60947-2 MCCB  Application       YCM1 series Circu breaker is suitable for the circuit of AC50/60Hz,rated current up to 630A,rated operating voltage 690V or less.The series circuit breaker in the distribution network,can be used for distributing the energy or electricity and protecting the circuit and power device against the overload,short circuit and undervoltage.the circuit breaker with frame rated cu...