Skip to main content

Distribution transformer / dry type epoxy resin 35 kV

Distribution transformer / dry type epoxy resin 35 kV
  
Skype : mark2002719  email: mark2002719@gmail.com

35kV Epoxy Resin Dry-type Transformer 

Application: for power distribution system and large industrial enterprises, etc. 
Standards: IEC 60076-11

Features:
 High security and reliability in operation. 
 Economic and efficient to reduce network loss and working cost. 
 Low temperature rise. 
 Low noise. 
 Operation in moist place with high moisture-proof capability. 
 Customized transformers are available on your requirement.

Technical Data:
 Rated Voltage: 35kV. 
 Rated Capacity: 50-20000kVA.
 Vector group: Dyn11/Yyn0/Yd11
 No-load loss: max. 25500W.
 Short-circuit impedance: max. 10%.


Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse with...

AC load-break switch / outdoor 40.5 kV | FZ77-40.5D/T1250-20 / FZR77-40.5D/T63-31.5

AC load-break switch / outdoor 40.5 kV | NFZ77-40.5D/T1250-20 / NFZR77-40.5D/T63-31.5 Skype : mark2002719   email : mark2002719@gmail.com FZ77-40.5D/T1250-20 / FZR77-40.5D/T63-31.5 Outdoor AC Vacuum Load Break Switch  Application: for making and breaking rated current and overload current, protecting the equipments from phase-loss fault in 35kV AC50Hz power system. Standards: IEC 60265-1, IEC 62271-105. Parameters:  Rated voltage: 40.5kV  Rated current: 1250A  Fuse current: 63A Features:   Compact design and light in weight.   High breaking capacity.   Maintenance-free.   Safety and reliable operation.   Long mechanical life.

DC to AC Solar Power Inverter

              DC to AC Solar Power Inverter Products Features 1. Input & output fully insolated 2. High Surge: High surge current capability starts difficult loads such as TVs, camps, motors and other inductive loads 3. Soft start: Smooth start-up of the appliances. 4. Pure sine wave output waveform: Clean power for sensitive loads. 5. AC output identical to, and in some cases better than the power supplied by your utility 6. Cooling fan in the inverter is thermally activated and comes on when the inverters becomes warm, and turns off automatically after the inverter has cooled. 7. Low total harmonic distortion: Below 3% 8. Two LED indicators on the front panel shows the working and failure state.