Skip to main content

ZW32 Vacuum circuit breaker / AC / outdoor 12 kV, max. 25 kA |

ZW32  Vacuum circuit breaker / AC / outdoor 12 kV, max. 25 kA | 

Skype : Mark2002719  email : Mark2002719@gmail.com
ZW32-12 Series Outdoor AC Vacuum Circuit Breaker 

Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments.
Standards: IEC 62271-100

Parameters:
Rated voltage: 12kV. 
Rated current: 630-1250A. 
Rated short-circuit breaking current: 20kA,25kA.

Features:
 Compact design and light in weight. 
 Enclosed construction can realize anti-dust and anti-moisture. 
 Maintenance-free. 
 Both manual and electric power operation and remote control.


Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse with...

Load-break switch 12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5

Load-break switch   12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5     Skype : mark2002719   emal : mark2002719@gmail.com FLN36-12D/630-20 SF6 Switch / FLRN36-12D/T125-31.5 SF6 Switch-fuse Combination Application: in the system of 50Hz, 12kV for making and breaking of load current, over-load current and short-circuit current to control and protect the circuit and transformer, etc. Standards: IEC 60265, IEC 60420 Features:  Indication of the active contact to show the operation status of the switch.   High insulation level.   Fully sealed and reliable operation. Technical Data:  Rated voltage(kV): 12  Rated current(A): FLN36-12D: 630; FLRN36-12D: 125  Rated frequency(Hz): 50  Rated short-time withstands current of switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/3  Rated short-time withstands current of earthing switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/2   Rated peak withstand curre...

DDS226D-4P Single-phase Din-rail Energy Meter

DDS226D-4P Single-phase Din-rail Energy Meter (same quality as Chint energy meter) DDS226D-4P Single-phase Din-rail Energy Meter (same quality as Chint energy meter) General DDS226D-4P type single-phase din-rail energy meter can accurately and directly measure 50Hz/60Hz active energy consumption from single phase AC electricity net with functions of good reliability, small volume, light weight, specious appearance,convenient installation, etc. All of the performances accord with the National Standard GB/T17215.321-2008 and International Standard IEC62053-21. Function and features  1.Measuring single phase total active energy power. 2.May select step motor type impulse register display 5+1 digits (99999.9KWh) or LCD 5+2 digits display, LCD 5+2(99999.99KWh), 5+1 digits(99999.9KWh) and 6+1 (999999.9KWh); 3.Passive impulse output, comply to DIN43864 Standard; 4.Two LED indicate power condition and energy impulse signal; 5.35mm standard DIN rail i...