Skip to main content

Distribution transformer / oil-filled 35 kV

   35kV Oil-immersed Distribution Transformer 

                                    SKype : mark2002719  email : mark202719@gmail.com
35kV Oil-immersed Distribution Transformer 

Application: for power distribution system and large scale industrial enterprises, etc.
Standards: IEC 60076-1, IEC 60076-2, IEC 60076-3, IEC 60076-5; ANSI, IEEE, AS, etc.

Parameters: 
Rated Voltage: 50/60Hz 35kV. 
Rated Capacity: 50-75000kVA.

Features:
 High security and reliability in operation.
 Economic and efficient to reduce network loss and working cost.
 High short circuit strength and insulating strength.
 Low temperature rise. Low noise.
 Customized transformers are available on your requirement.
 Competitive short delivery time.

Rated capacity (kVA): 1000 to 31500
Rated voltage and tapping range:
- HV: 35 to 8.5
- Tapping range: ±3×2.5
- LV: 6.3 to 11
Vector group: Yd11, YNd11
No load losses (kW): 1.3 to 21
On load losses (kW): 11.1 to 117
Impedance voltage (%): 6.5 to 8.0
No load current (%): 1.1 to 0.45

* All the data are only examples for your reference.
* Customized transformers are available according to your requirements.

Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse withstand vol

Load-break switch 12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5

Load-break switch   12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5     Skype : mark2002719   emal : mark2002719@gmail.com FLN36-12D/630-20 SF6 Switch / FLRN36-12D/T125-31.5 SF6 Switch-fuse Combination Application: in the system of 50Hz, 12kV for making and breaking of load current, over-load current and short-circuit current to control and protect the circuit and transformer, etc. Standards: IEC 60265, IEC 60420 Features:  Indication of the active contact to show the operation status of the switch.   High insulation level.   Fully sealed and reliable operation. Technical Data:  Rated voltage(kV): 12  Rated current(A): FLN36-12D: 630; FLRN36-12D: 125  Rated frequency(Hz): 50  Rated short-time withstands current of switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/3  Rated short-time withstands current of earthing switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/2   Rated peak withstand current and rated short-circuit making

rccb circuit breaker F364 30ma

F364 30ma  electrical rccb 1.Manufactory Profile: CNC electric Co., Ltd is a professional manufacturer of low voltage electrical producs and materials in China, We specialize in this field for 15 years. As our products quality are stable & reliable, prices are reasonable and service also fine,  most of them sells very good in UK, Iran, Pakistan, India, Bangladesh,Dubai, Thailand, Zambia and so on.  We also have considerable experience on R&D, design and OEM, besides the current products, we also can supply made to meansure products to your sample. You are welcome to call consultations, negotiations.     2.Basic Parameters: Standrad IEC/EN61008 Mode Electro-magnetic type,electronic type Type(wave form of the earth leakage sensed) AC,A Rated current ln 16,25,32,40,63A Poles 2,4P Rated voltage Ue AC240/415 lnsulation voltage Ui 500V Rated frequency 50/60Hz Electrical life 6000t Mechanical life 10000t Fault current inditor