XGN15-12 Package AC Metal Enclosed Loop Switchgear, Fixed Type



XGN15-12 Package AC Metal Enclosed Loop Switchgear, Fixed Type

General
1. Rating: Rated voltage 12KV, rated current reach to 630A.
2. Application :mainly applicable in urban power grid construction and renovation
project. industrial and mining enterprises.high-rise buildings and communal facilities .For power distribution .controlling and protection on electric equipment as the loop power supply unit or termina equipment. It also can be installed in preloaded substation
4. Feature: Use SF6 load switch and load switch-fuse combination as main switch.
5. Equipped with vacuum load switch and spring operating mechanism which can be operated by hand or electric. Earthing switch and insulating switch are equipped with hand operating mechanism. With small volume and high security
6. Standard: IEC60420

Working Conditions
1. Ambient air temperature: -15°C~+40°C.
2. Daily average temperature:≤35°C.
2. Altitude: ≤1000m.
4. Relative humidity : Daily average≤95% ,daily averange of vapour pressure≤2.2kpa
5. Monthly average≤90%,monthly averange of vapour pressure≤1.8kpa.
6. Earthquake intensity: ≤magnitude 8.
7. Applicable in the places without corrosive and flammable gas.
Note: Customized products are available.




Structural feature
1. SF6 load switch with insulated enclosure FLN36-13D and FLRN36-12D could be matched in switchgear.
2. Compact design and easy operation.
3. There is a pressure reliefing duct at the rear of the switchgear to protect the operator when a failure occurs in the switchgear.
4. Allocation of the switchgear is changeable.
5. Reliable interlocking at the different making status of the loading switch, earthing switch to ensure the reliable operation





Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse with...

AC load-break switch / outdoor 40.5 kV | FZ77-40.5D/T1250-20 / FZR77-40.5D/T63-31.5

AC load-break switch / outdoor 40.5 kV | NFZ77-40.5D/T1250-20 / NFZR77-40.5D/T63-31.5 Skype : mark2002719   email : mark2002719@gmail.com FZ77-40.5D/T1250-20 / FZR77-40.5D/T63-31.5 Outdoor AC Vacuum Load Break Switch  Application: for making and breaking rated current and overload current, protecting the equipments from phase-loss fault in 35kV AC50Hz power system. Standards: IEC 60265-1, IEC 62271-105. Parameters:  Rated voltage: 40.5kV  Rated current: 1250A  Fuse current: 63A Features:   Compact design and light in weight.   High breaking capacity.   Maintenance-free.   Safety and reliable operation.   Long mechanical life.

DC to AC Solar Power Inverter

              DC to AC Solar Power Inverter Products Features 1. Input & output fully insolated 2. High Surge: High surge current capability starts difficult loads such as TVs, camps, motors and other inductive loads 3. Soft start: Smooth start-up of the appliances. 4. Pure sine wave output waveform: Clean power for sensitive loads. 5. AC output identical to, and in some cases better than the power supplied by your utility 6. Cooling fan in the inverter is thermally activated and comes on when the inverters becomes warm, and turns off automatically after the inverter has cooled. 7. Low total harmonic distortion: Below 3% 8. Two LED indicators on the front panel shows the working and failure state.