Skip to main content

KYN28A




















KYN28A-12(Z)(GZS1) Metalclad AC Enclosed Switchgear


General
1.Ratings: system voltage 3.6kV, 7.2KV, 12KV, rated current up to 4000A, AC three
phase 50/60HZ.
2.Application: mainly applicable in the power plant, substation, mineral    enterprise to receive and distribute power with the functions of controlling,    protecting and monitoring. It also can be used in places where the frequently    operations are in need.
3.Standard: IEC62271-200

Working Conditions

1.Ambient air temperature: -15℃~+40℃.
2.Altitude: ≤1000m.
3.Relative humidity : Daily average≤95%, daily averange of vapour    pressure≤2.2kpa.
4.Earthquake intensity: ≤magnitude 8.
5.Applicable in the places without corrosive and flammable gas and water vapor.
6.Used in place without frequently intense vibrant.

Note: Customized products are available.

Comments

Popular posts from this blog

SF6 gas insulated circuit breaker / high-voltage 40.5 kV | LW8

SF6 gas insulated circuit breaker / high-voltage  40.5 kV | LW8 Skype : mark2002719   email : mark2002719@gmail.com LW8 40.5 kV SF6 Circuit Breaker Application: for control and protection of 40.5 kV power system. Ratings: 40.5kV, 2000A Standards: IEC 62271-100 Features:  With CT14 spring operation mechanism.  High breaking capacity.  Secure and reliable operation.  Applicable for frequent operation; easy or free of maintenance. Technical Data: Rated voltage (kV):40.5 Rated current (A): 2000 Rated short-circuit breaking current for Isc: 31.5; 25; 31.5; 25 Rated short-time withstands current/continuous time (kA/s): 31.5/4; 25/4; 31.5/4; 25/4 Rated withstands current (peak): 80; 63; 80; 63 Rated short-circuit making current (peak) (kA): 80; 63; 80; 63 Power frequency withstands voltage for 1min (Breaks) (kV): 95+24; 95; 95; 95 Power frequency withstands voltage for 1min (To earth) (kV): 95; 95; 95; 95 Lighting impulse withstand vol

Load-break switch 12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5

Load-break switch   12 kV, 630 A | FLN36-12D/630-20, FLRN36-12D/T125-31.5     Skype : mark2002719   emal : mark2002719@gmail.com FLN36-12D/630-20 SF6 Switch / FLRN36-12D/T125-31.5 SF6 Switch-fuse Combination Application: in the system of 50Hz, 12kV for making and breaking of load current, over-load current and short-circuit current to control and protect the circuit and transformer, etc. Standards: IEC 60265, IEC 60420 Features:  Indication of the active contact to show the operation status of the switch.   High insulation level.   Fully sealed and reliable operation. Technical Data:  Rated voltage(kV): 12  Rated current(A): FLN36-12D: 630; FLRN36-12D: 125  Rated frequency(Hz): 50  Rated short-time withstands current of switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/3  Rated short-time withstands current of earthing switch/ Rated continuous time of short-circuit(kA/s): FLN36-12D: 20/2   Rated peak withstand current and rated short-circuit making

rccb circuit breaker F364 30ma

F364 30ma  electrical rccb 1.Manufactory Profile: CNC electric Co., Ltd is a professional manufacturer of low voltage electrical producs and materials in China, We specialize in this field for 15 years. As our products quality are stable & reliable, prices are reasonable and service also fine,  most of them sells very good in UK, Iran, Pakistan, India, Bangladesh,Dubai, Thailand, Zambia and so on.  We also have considerable experience on R&D, design and OEM, besides the current products, we also can supply made to meansure products to your sample. You are welcome to call consultations, negotiations.     2.Basic Parameters: Standrad IEC/EN61008 Mode Electro-magnetic type,electronic type Type(wave form of the earth leakage sensed) AC,A Rated current ln 16,25,32,40,63A Poles 2,4P Rated voltage Ue AC240/415 lnsulation voltage Ui 500V Rated frequency 50/60Hz Electrical life 6000t Mechanical life 10000t Fault current inditor